Output ratingsMax.
current
Input
rating
FrameACS580-
01-…
Heavy-duty useLight-duty useNominal use
P
Hd
I
Hd
P
Ld
I
Ld
P
n
I
2
I
max
I
1
kWAkWAkWAAA
3-phase
U
n
= 400 V (380…415 V)
0.61.80.752.50.752.63.22.6R102A7-4
0.82.61.13.11.13.34.73.3R103A4-4
1.13.31.53.81.54.05.94.0R104A1-4
1.54.02.25.32.25.67.25.6R105A7-4
2.25.63.06.83.07.210.17.2R107A3-4
3.07.24.08.94.09.413.09.4R109A5-4
4.09.45.512.05.512.615.312.6R112A7-4
5.512.67.516.27.517.022.717.0R2018A-4
7.517.011.023.811.025.030.625.0R2026A-4
11.024.615.030.415.032.044.332.0R3033A-4
15.031.618.536.118.538.056.938.0R3039A-4
18.537.722.042.822.045.067.945.0R3046A-4
2245305830628162R4062A-4
2245305830628162R4 v2062A-4
30613768377311073R4073A-4
30613768377311073R4 v2073A-4
37724583458813088R5088A-4
37724583458913089R4 v2089A-4
45875510055106157106R5106A-4
551057513875145178145R6145A-4
751459016190169247169R7169A-4
90169110196110206287206R7206A-4
110206132234132246350246R8246A-4
132246
1)
160278160293418293R8293A-4
160293200345200363498363R9363A-4
200363
2)
200400250430545430R9430A-4
268 Technical data