Reference resistor types
P
BRmax
R
max
R
min
ACS580-01-…
hpkWohmohm
Danotherm CBH 360 C T 406 210R0.80.68645202A1-4
Danotherm CBH 360 C T 406 210R1.20.95825203A0-4
Danotherm CBH 360 C T 406 210R1.91.43925203A5-4
Danotherm CBH 360 C T 406 210R2.72.02795204A8-4
Danotherm CBR-V 330 D T 406 78R UL3.92.91915206A0-4
Danotherm CBR-V 330 D T 406 78R UL5.23.91405207A6-4
Danotherm CBR-V 330 D T 406 78R UL7.15.310452012A-4
Danotherm CBR-V 560 D HT 406 39R UL9.87.37531014A-4
Danotherm CBR-V 560 D HT 406 39R UL13.6105222023A-4
Danotherm CBT-H 560 D HT 406 19R20.1153716027A-4
Danotherm CBT-H 760 D HT 406 16R26.8202710034A-4
Danotherm CBT-H 760 D HT 406 16R33.5252210044A-4
3-phase
U
1
= 525…600 V,
P
n
at
U
n
= 575 V
Danotherm CBR-V 330 D T 406 78R UL2.091.56006002A7-6
Danotherm CBR-V 330 D T 406 78R UL2.72.24506003A9-6
Danotherm CBR-V 330 D T 406 78R UL5.44.02256006A1-6
Danotherm CBR-V 330 D T 406 78R UL7.25.41656009A0-6
Danotherm CBR-V 330 D T 406 78R UL9.97.412060011A-6
Danotherm CBR-V 330 D T 406 78R UL14.7118260017A-6
Danotherm CBR-V 560 D HT 406 39R UL21.4165625022A-6
Danotherm CBR-V 560 D HT 406 39R UL28.2214325027A-6
TBD34.9263525032A-6
Symbols
= minimum allowed brake resistor that can be connected to the brake chopper
R
min
= maximum allowed brake resistor that allows P
BRmax
R
max
= maximum braking capacity of the drive, must exceed the desired braking power.
P
BRmax
WARNING!
Do not use a brake resistor with a resistance below the minimum value
specified for the particular drive. The drive and the internal chopper are not
able to handle the overcurrent caused by the low resistance.
402 Resistor braking