Note: The height of the hood for frames R4 and R9 exceeds the requirement
of free space above for these frames
Hood height (in)Hood height (mm)Frame size
2.8372R4
9.06230R9
2)
Free space below is always measured from the drive frame, not from the
cable box.
3)
Free space between the drive and other objects, e.g. wall.
Note: The recommended free space above and below the drive is for
installations where the drive is mounted on a wall indoors. For ABB cabinet-built
drives, which are thermally tested and approved for a specified temperature
range, free space could vary from this recommendation.
Vertical installation - Free space, IP66 (UL Type 4X)Frame size
Beside (c)Below (b)Above (a)
inmminmminmm
5.91502.0502.665R1
5.91502.0502.665R2
5.91502.0502.665R3
• Vertical side by side or between walls