Mechanical installation of pre-assembled units (ACS800-04/U4)
43
View of output busbar connections of frame size R7 (DC and brake busbars included)
Plain washer with
electroplated zinc coating
and yellow chromate
passivation
2
Spring washer with
mechanically sprayed zinc
coating
Nut
M10x30
1
Tightening torques
M8: 15...22 Nm (3.7 lbf ft)
M10: 30...44 Nm (22...32 lbf ft)
M8
WARNING! The output busbars are fastened to the insulating supports with M8x16 screws
when no cable lug terminal is connected, but with M8x20 screws when a cable lug terminal
is also connected with the same screw. Screwing an M8x20 screw without a cable lug
terminal through the busbar into the insulating support will break the insulating support.
Fasten the cable lug terminals elsewhere with M10x25 screws.
M8x16
M8x20
M10x25
Cable lug
terminal
Insulating support
2
Tightened at the factory
Top view of insulating support and cable
lug terminal connections