Actual signals and parameters
101
60.04 WEB LOSS DELAY Time after detection occurs before a digital output (03.15 PACK
STATUS BITS bit 00) is set. See chapter Fieldbus control.
Web Loss is calculated three different ways:
DANCER CONTROL
Trip occurs if Dancer moves to its maximum position signifying loss of
tension on the web. This would be a low value at the input to the drive.
TENSION CONTROL
Trip occurs if actual tension drops below trip percentage (60.03
WEBLOSS TRIP) of 63.14 MAXIMUM TENSION. Select Tension
Control when loadcells are used for actual tension feedback.
TORQUE CONTROL
Trip occurs if the actual torque % drops below trip percentage (60.03
WEBLOSS TRIP) of the available motor torque. Select Torque Control
when actual tension feedback is not available.
0…100.0 s Setting range. 10 = 1 s
60.05 WINDING MODE When setting up the drive, keep the following in mind. The software
assumes the motor is set up as one of the following:
The program defaults the following parameters based on the above
assumption:
If the web needs to go in the opposite direction, change DIRECTION.
If the drive is an Underwind, change 60.05 WINDING MODE. If the
dancer/loadcell is on the opposite side of web flow with respect to the
drive, change REVERSE REG OUT (62.0863.08).
OVER Overwind is selected. 1
UNDER Underwind is selected. 2
DI2 – UNDER Digital input DI2 = 1 selects Underwind. 3
DI3 – UNDER See selection DI2 - UNDER. 4
DI4 – UNDER See selection DI2 - UNDER. 5
DI5 – UNDER See selection DI2 - UNDER. 6
DI6 – UNDER See selection DI2 - UNDER. 7
DI7 – UNDER See selection DI2 - UNDER. 8
DI8 – UNDER See selection DI2 - UNDER. 9
DI9 – UNDER See selection DI2 - UNDER. 10
DI10 – UNDER See selection DI2 - UNDER. 11
DI11 – UNDER See selection DI2 - UNDER. 12
DI12 – UNDER See selection DI2 - UNDER. 13
FBUS – UNDER See selection DI2. Instead of a digital input, the selection comes from
06.03 DATASET 1 WORD 3 bit 14. See chapter Fieldbus control.
14
61 CORE SPEED MATCH
Used to match the speed of a core to line speed in automatic roll
change machines.
61.01 SPD MTCH REF SEL Selects the signal source for the reference value for the speed match
trim amount.
NOT SEL Speed matching function is not used. 1