Actual signals and parameters
121
DI4 See selection DI2. 4
DI5 See selection DI2. 5
DI6 See selection DI2. 6
DI7 See selection DI2. 7
DI8 See selection DI2. 8
DI9 See selection DI2. 9
DI10 See selection DI2. 10
DI11 See selection DI2. 11
DI12 See selection DI2. 12
FIELDBUS See selection DI2. Instead of a digital input, the command comes from
06.03 DATASET 1 WORD 3 bit 10. See chapter Fieldbus control.
13
65.14 CALC DIA USING Selects whether the internal diameter calculator is used or if an
external sensor is used.
INTERNAL Internal calculator. 0
PARAM 65.21 External sensor using input selected by 65.21 EXT DIA SEL. 65535
65.15 SENSOR MIN DIA Allows the minimum measured value of the sensor to represent
something other than 0 mm.
0.0…99999.0 mm
0.0…99999.0 inch
Setting range. 10 = 1 mm
10 = 1 inch
65.16 DIA > LIM1 When the calculated diameter value is greater than this limit, 03.15
PACK STATUS BITS bit 11 is active. See chapter Fieldbus control.
1.0…99999.0 mm
1.0…99999.0 inch
Setting range. 10 = 1 mm
10 = 1 inch
65.17 DIA > LIM2 When the calculated diameter value is greater than this limit, 03.15
PACK STATUS BITS bit 12 is active. See chapter Fieldbus control.
1.0…99999.0 mm
1.0…99999.0 inch
Setting range. 10 = 1 mm
10 = 1 inch
65.18 DIA < LIM1 When the calculated diameter value is less than this limit, 03.15
PACK STATUS BITS bit 13 is active. See chapter Fieldbus control.
1.0…99999.0 mm
1.0…99999.0 inch
Setting range. 10 = 1 mm
10 = 1 inch
65.19 DIA < LIM2 When the calculated diameter value is less than this limit, 03.15
PACK STATUS BITS bit 14 is active. See chapter Fieldbus control.
1.0…99999.0 mm
1.0…99999.0 inch
Setting range. 10 = 1 mm
10 = 1 inch
65.20 RESET WHILE RUN Allows the calculated diameter value to be reset while the machine is
running.
NO Not allowed. 0
YES Allowed. 65535
65.21 EXT DIA SEL Selects which input a diameter sensor is connected to. Used for
diameter reset and/or calculation.
AI1 Uses a sensor on analog input AI1 (voltage). 1
AI2 Uses a sensor on analog input AI2 (current). 2
AI3 Uses a sensor on analog input AI3 (current). 3
AI5 Uses a sensor on analog input AI5 (voltage or current). 4
No. Name/Value Description FbEq