EasyManua.ls Logo

ABB ACS800 Series - Page 135

ABB ACS800 Series
214 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Actual signals and parameters
123
PARAM 66.07 Source selected by 66.07 TORQ MEM SMPL PTR. 14
66.02 TORQUE MEM ENABLE Selects the activation signal source to use the memorized torque as
the torque reference.
NOT SEL Torque memory is not used. 1
DI2 Digital input DI2 = 1 selects the memorized torque as the torque
reference.
2
DI3 See selection DI2. 3
DI4 See selection DI2. 4
DI5 See selection DI2. 5
DI6 See selection DI2. 6
DI7 See selection DI2. 7
DI8 See selection DI2. 8
DI9 See selection DI2. 9
DI10 See selection DI2. 10
DI11 See selection DI2. 11
DI12 See selection DI2. 12
FIELDBUS See selection DI2. Instead of a digital input, the command comes from
06.03 DATASET 1 WORD 3 bit 12. See chapter Fieldbus control.
13
PARAM 66.08 Source selected by 66.08 TORQ MEM ENABL PTR. 14
66.03 TORQUE BOOST SEL Sets or selects the activation signal source to enable the torque boost.
ON DELAY The torque boost is activated once the 66.04 BOOST ON DELAY has
expired.
1
DI2 Digital input DI2 = 1 enables the torque boost. 2
DI3 See selection DI2. 3
DI4 See selection DI2. 4
DI5 See selection DI2. 5
DI6 See selection DI2. 6
DI7 See selection DI2. 7
DI8 See selection DI2. 8
DI9 See selection DI2. 9
DI10 See selection DI2. 10
DI11 See selection DI2. 11
DI12 See selection DI2. 12
FIELDBUS See selection DI2. Instead of a digital input, the command comes from
06.03 DATASET 1 WORD 3 bit 13. See chapter Fieldbus control.
13
66.04 BOOST ON DELAY Delay timer that starts once 66.02 TORQUE MEM ENABLE is
activated.
0.0…1000.0 s Setting range. 10 = 1 s
66.05 TORQUE BOOST % Percentage of the memorized torque. Used as the torque reference is
66.02 TORQUE MEM ENABLE and 66.03 TORQUE BOOST SEL are
active.
50…1000% Setting range. 1 = 1%
66.06 MTR TQ FILT TIME Filter time for the torque used for torque sample.
2…20000 ms Setting range. 1 = 1 ms
No. Name/Value Description FbEq

Table of Contents

Other manuals for ABB ACS800 Series

Related product manuals