Actual signals and parameters
124
66.07 TORQ MEM SMPL PTR Defines the source or constant for selection PARAM 66.07 of
66.01 TORQUE MEM SAMPLE.
-255.255.31…+255.255.31
/ C.-32768…C.32767
Parameter index or a constant value. See 10.05 EXT1 STRT PTR for
information on the difference.
-
66.08 TORQ MEM ENBL PTR Defines the source or constant for selection PARAM 66.08 of
66.02 TORQUE MEM ENABLE.
-255.255.31…+255.255.31
/ C.-32768…C.32767
Parameter index or a constant value. See 10.05 EXT1 STRT PTR for
information on the difference.
-
67 LEAD CTRL
Winder Lead macro specific parameters.
Note: This group is hidden unless WINDER LD MACRO is selected
67.01 WEB SPD INPUT Selects the signal source for the web speed feedback.
NOT SEL Not selected. 1
AI1 Analog input AI1 (voltage). 2
AI2 Analog input AI2 (current). 3
AI3 Analog input AI3 (current). 4
AI5 Analog input AI5 (voltage or current). 5
AI6 Analog input AI6 (voltage or current). 6
67.02 WEB SPD SCALE Scales the AI maximum (10 VDC / 20 mA) to motor speed at core.
0…9999.0 Setting range. 10 = 1
70 DDCS CONTROL
Settings for the fiber optic channels.
70.01 CH0 NODE ADDR Defines the node address for channel 0. No two nodes on-line may
have the same address. The setting needs to be changed when a
master station is connected to channel 0 and it does not automatically
change the address of the slave. Examples of such masters are an
ABB Advant Controller or another drive.
0…254 Address. 1 = 1
70.02 CH0 BAUD RATE The communication speed of channel 0.
8 Mbit/s 8 megabits per second. 0
4 Mbit/s 4 megabits per second. 1
2 Mbit/s 2 megabits per second. 2
1 Mbit/s 1 megabits per second. 3
70.05 CH2 NODE ADDR Defines the node address for channel 2.
1…125 Setting range. 1 = 1
70.06 CH2 M/F MODE Selects how the drive will use CH2 in a Master/Follower ring.
NOT IN USE CH2 is not used. 1
MASTER The drive is the master of the ring. 2
FOLLOWER The drive is a follower and receives the data sent from the Master as
defined in the Master’s master signal 1, 2, and 3.
3
SPD FOLLOWER See selection FOLLOWER. The speed reference of the drive is
automatically set to follow the master, regardless of the setting in
11.03 EXT1 REF SELECT.
4
SPDTQ FOLLOW See selection SPD FOLLOWER. The torque reference of the drive is
automatically set to follow the master.
5
70.07 MASTER SIGNAL 1 Signal pointer for high speed dataset communications to followers as
command word.
No. Name/Value Description FbEq