Fieldbus control
142
After the module configuration parameters in group 51 have been set, the drive
control parameters (section The fieldbus control interface on page 147) must be
checked and adjusted where necessary.
The new settings will take effect when the drive is next powered up, or when
parameter 51.27 is activated.
51.30 FILE
CONFIG REV*
xyz (binary
coded decimal)
– Displays the fieldbus adapter module
configuration file revision stored in the
memory of the drive.
x = major revision number;
y = minor revision number;
z = correction number.
Example: 1 = revision 0.01.
51.31 FBA
STATUS*
(0) IDLE
(1) EXEC. INIT
(2) TIME OUT
(3) CONFIG
ERROR
(4) OFF-LINE
(5) ON-LINE
(6) RESET
– Displays the status of the adapter module.
IDLE = Adapter not configured.
EXEC. INIT = Adapter initializing.
TIME OUT = A time out has occurred in
the communication between the adapter
and the drive.
CONFIG ERROR = Adapter configuration
error. The major or minor revision code of
the CPI program revision in the drive is
not the revision required by the module
(refer to par. 51.32) or configuration file
upload has failed more than five times.
OFF-LINE = Adapter is off-line.
ON-LINE = Adapter is on-line.
RESET = Adapter performing a hardware
reset.
51.32 FBA CPI FW
REV*
– – Displays the CPI program revision of the
module inserted in slot 1.
x = major revision number;
y = minor revision number;
z = correction number.
Example: 107 = revision 1.07.
51.33 FBA APPL
FW REV*
– – Displays the control program revision of
the module inserted in slot 1.
x = major revision number;
y = minor revision number;
z = correction number.
Example: 107 = revision 1.07.
*Parameters 51.27 to 51.33 are only visible when type Rxxx fieldbus adapter is installed.
Parameter Alternative
Settings
Setting for
Fieldbus
Control
Function/Information