Additional data: actual signals and parameters
175
Additional data: actual signals and parameters
Chapter overview
This chapter lists the actual signal and parameter lists with some additional data. For
the descriptions, see chapter Actual signals and parameters.
Terms and abbreviations
Fieldbus addresses
Rxxx adapter modules (such as RPBA-01, RDNA-01, etc.)
See the appropriate fieldbus adapter module User’s Manual.
Nxxx adapter modules (such as NPBA-12, NDNA-02, etc.)
NPBA-12 Profibus Adapter:
All versions
see column PB in the tables below.
Version 1.5 or later
see NPBA-12 PROFIBUS Adapter Installation and Start-Up
Guide [3BFE64341588 (English)].
NIBA-01 InterBus-S Adapter:
xxyy
· 100 + 12288 converted into hexadecimal, where xxyy = drive parameter
number
Example: The index number for drive parameter 13.09 is 1309 + 12288 = 13597
(dec) = 351D (hex)
NMBP-01 ModbusPlus Adapter and NMBA-01 Modbus Adapter:
4xxyy, where xxyy = drive parameter number
Term Definition
PB Parameter address for the fieldbus communication through a
Profibus link (Add 4000 in FMS Mode).
FbEq Fieldbus equivalent: The scaling between the value shown on
the panel and the integer used in serial communication.
Absolute Maximum Frequency Value of 20.08 FREQUENCY MAX, or 20.07 FREQUENCY MIN
if the absolute value of the minimum limit is greater than the
maximum limit.
Absolute Maximum Speed Value of parameter 20.02 MAXIMUM SPEED, or 20.01
MINIMUM SPEED if the absolute value of the minimum limit is
higher than the maximum limit.