Additional data: actual signals and parameters
180
15 ANALOG OUTPUTS
15.01 A01 POINTER +.001.004.00 +.001.004.00 +.001.004.00 +.001.004.00 +.001.004.00 226
15.03 MINIMUM AO1 0 mA 0 mA 0 mA 0 mA 0 mA 228
15.04 FILTER AO1 ms 500 500 500 500 500 229
15.05 NOM VALUE AO1 100.0 100.0 100.0 100.0 100.0 230
15.06 A02 POINTER +.001.002.00 +.001.002.00 +.001.002.00 +.001.002.00 +.001.002.00 231
15.08 MINIMUM AO2 0 mA 0 mA 0 mA 0 mA 0 mA 233
15.09 FILTER AO2 ms 500 500 500 500 500 234
15.10 NOM VALUE AO2 1800.0 1800.0 1800.0 1800.0 1800.0 235
15.11 A03 POINTER +.001.004.00 +.001.004.00 +.001.004.00 +.001.004.00 +.001.004.00 236
15.13 MINIMUM AO3 0 mA 0 mA 0 mA 0 mA 0 mA 238
15.14 FILTER AO3 ms 500 500 500 500 500 239
15.15 NOM VALUE AO3 100.0 100.0 100.0 100.0 100.0 240
15.16 A04 POINTER +.001.002.00 +.001.002.00 +.001.002.00 +.001.002.00 +.001.002.00 241
15.18 MINIMUM AO4 0 mA 0 mA 0 mA 0 mA 0 mA 243
15.19 FILTER AO4 ms 500 500 500 500 500 244
15.20 NOM VALUE AO4 1800.0 1800.0 1800.0 1800.0 1800.0 245
16 SYS CTRL INPUTS
16.01 RUN ENABLE YES YES YES YES YES 251
16.02 PARAMETER LOCK OPEN OPEN OPEN OPEN OPEN 252
16.03PASS CODE 00000253
16.04 FAULT RESET SEL DI6 DI6 DI6 DI6 DI6 254
16.05 USER MACRO IO CHG NOT SEL NOT SEL NOT SEL NOT SEL NOT SEL 255
16.06 LOCAL LOCK OFF OFF OFF OFF OFF 256
16.07 PARAMETER SAVE DONE DONE DONE DONE DONE 257
16.09 CTRL BOARD SUPPLY INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL 259
20 LIMITS
20.01 MINIMUM SPEED (calculated) (calculated) (calculated) (calculated) (calculated) 351
20.02 MAXIMUM SPEED (calculated) (calculated) (calculated) (calculated) (calculated) 352
20.03 MAXIMUM CURRENT 200.0% I
hd
200.0% I
hd
200.0% I
hd
200.0% I
hd
200.0% I
hd
353
20.04 MAXIMUM TORQUE 300.0% 300.0% 300.0% 300.0% 300.0% 354
20.05 OVERVOLTAGE CTRL ON ON ON ON ON 355
20.06 UNDERVOLTAGE CTRL ON ON ON ON ON 356
20.07* FREQUENCY MIN [Hz] -50.00 Hz -50.00 Hz -50.00 Hz -50.00 Hz -50.00 Hz 357
20.08* FREQUENCY MAX [Hz] 50.00 Hz 50.00 Hz 50.00 Hz 50.00 Hz 50.00 Hz 358
20.10 MINIMUM TORQUE -600.0% -600.0% -600.0% -600.0% -600.0% 369
20.11 P MOTORING LIM 300.0% 300.0% 300.0% 300.0% 300.0% 361
20.12 P GENERATING LIM -300.0% -300.0% -300.0% -300.0% -300.0% 362
20.13 MIN TORQ SEL NEG MAX
TORQ
NEG MAX
TORQ
NEG MAX
TORQ
NEG MAX
TORQ
NEG MAX
TORQ
363
20.14 MAX TORQ SEL MAX LIM1 MAX LIM1 MAX LIM1 MAX LIM1 MAX LIM1 364
20.15 TORQ MIN LIM1 0.0% 0.0% 0.0% 0.0% 0.0% 365
20.16 TORQ MIN LIM2 0.0% 0.0% 0.0% 0.0% 0.0% 366
20.17 TORQ MAX LIM2 300.0% 300.0% 300.0% 300.0% 300.0% 367
20.18TORQ MIN PTR00000368
20.19TORQ MAX PTR00000369
20.20 MIN AI SCALE 0% 0% 0% 0% 0% 370
20.21 MAX AI SCALE 300% 300% 300% 300% 300% 371
21 START/STOP
21.01 START FUNCTION CNST DC
MAGN
CNST DC
MAGN
CNST DC
MAGN
CNST DC
MAGN
CNST DC
MAGN
376
21.02 CONST MAGN TIME 500.0 ms 500.0 ms 500.0 ms 500.0 ms 500.0 ms 377
21.03 STOP FUNCTION RAMP STOP RAMP STOP RAMP STOP RAMP STOP RAMP STOP 378
21.04 DC HOLD NO NO NO NO NO 379
21.05 DC HOLD SPEED 5 rpm 5 rpm 5 rpm 5 rpm 5 rpm 380
21.06 DC HOLD CURR 30.0% 30.0% 30.0% 30.0% 30.0% 381
Index Name/Selection UNWIND
TENSION
UNWIND
DANCER
WINDER
TENSION
WINDER
DANCER
WINDER
LEAD
PB