Program features
27
Programmable analog inputs
The drive has three programmable analog inputs: one voltage input (0/2…10 V) and
two current inputs (0/4…20 mA). Two extra inputs are available if an optional Analog
I/O Extension Module is used. Each input can be inverted and filtered, and the
maximum and minimum values can be adjusted.
Update cycles in the Control Program
Settings
Diagnostics
Input Cycle
AI / standard 10 ms
AI / extension 10 ms
Parameter Additional Information
Group 11 REFERENCE SELECT Reference source
Group 13 ANALOG INPUTS Processing of the standard inputs
35.01 Motor temperature measurement
Group 61 CORE SPEED MATCH Matching reference source
Group 62 DANCER CONTROLS Reference and feedback sources
Group 63 TENSION CONTROLS Reference and feedback sources
Group 65 DIA CALC CONTROL Diameter actual source
Group 67 LEAD CTRL Web speed source
98.06 Activation of optional analog inputs
Actual Value Additional Information
01.18…01.20 Standard inputs
01.38, 01.39 Optional inputs