Actual signals and parameters
67
06.04 DATASET 3 WORD 1 A 16-bit data word. Dancer / Tension setpoint (see 62.10 DANCER
LOAD SETPT and 63.10 TENSION SETPOINT).
1 = 1
06.05 DATASET 3 WORD 2 A 16-bit data word. Taper reference (see 62.12 TAPER REF SELECT
and 63.12 TAPER REF SELECT).
1 = 1
06.06 DATASET 3 WORD 3 A 16-bit data word. Speed match trim a mount (see 61.01 SPD MTCH
REF SEL).
1 = 1
06.07 DATASET 5 WORD 1 A 16-bit data word. Percent Draw Trim for progressive. Draw from
overriding controller.
1 = 1
06.08 DATASET 5 WORD 2 A 16-bit data word. See 90.08 DATA 5 WORD 2. 1 = 1
06.09 DATASET 5 WORD 3 A 16-bit data word. See 90.09 DATA 5 WORD 3. 1 = 1
09 ACTUAL SIGNALS
Signals for the Adaptive Program
09.01 AI1 SCALED Value of analog input AI1 scaled to an integer value. 2000 = 1 V
09.02 AI2 SCALED Value of analog input AI2 scaled to an integer value. 1000 = 1 mA
09.03 AI3 SCALED Value of analog input AI3 scaled to an integer value. 1000 = 1 mA
09.04 AI5 SCALED Value of analog input AI5 scaled to an integer value. 1000 = 1 mA
09.05 AI6 SCALED Value of analog input AI6 scaled to an integer value. 1000 = 1 mA
09.06 LCU ACT SIGNAL 1 A 16-bit data word. Line-side converter signal selected by 95.08 LCU
PAR1 SEL.
1 = 1
09.07 LCU ACT SIGNAL 2 A 16-bit data word. Line-side converter signal selected by 95.09 LCU
PAR2 SEL.
1 = 1
10 START/STOP/DIR
The sources for external start, stop and direction control
10.01 EXT1 STRT/STOP Defines the connections and the source of the start and stop
commands for external control location 1.
NOT SEL This function is not selected. 1
DI1 Start and stop through digital input DI1. 0 = stop; 1 = start.
WARNING! After a fault reset, the drive will start if DI1 = 1.
2
DI1P,2P Pulse start through DI1. Transition from 0 to 1 = start.
Pulse stop through DI2. Transition from 1 to 0 = stop.
3
DI7 See selection DI1. 4
FIELDBUS See selection DI1. Instead of a digital input, the command comes from
06.01 DATASET 1 WORD 1 bit 03. See chapter Fieldbus control.
5
MASTER DRV Starts and stops with the master drive. 6
FBA & DI1 Starts if DI1 and
FIELDBUS = 1. Stops if DI1 or FIELDBUS = 0. 7
MSTR & DI1 Starts if DI1 = 1 and
MASTER DRV starts. Stops if DI1 = 0 or MASTER
DRV stops.
8
FBA & MSTR Starts if FIELDBUS = 1 and
MASTER DRV starts. Stops if FIELDBUS
= 0 or
MASTER DRV stops.
9
PARAM 10.05 Source selected by 10.05 EXT 1 STRT PTR. 10
10.02 EXT1 DIRECTION Enables the control of direction of rotation of the motor, or fixes the
directIon. See 60.05 WINDING MODE to ensure this is the parameter
to change.
FORWARD Fixed to forward. 1
DI2 If digital input DI2 = 1, the direction is reverse. 2
DI3 See selection DI2. 3
DI4 See selection DI2. 4