Quick Start-up Guide for ACS850 with Standard Control Program 15
Select the source to switch between acceleration/
deceleration ramp pairs 1 and 2.
0 = Acceleration time 1/Deceleration time 1 are in
force, 1 = Acceleration time 2/Deceleration time 2
are in force.
22.01 Acc/Dec sel
Torque reference set-up
Select the source of the torque reference signal. 24.01 Torq ref1 sel
Define the maximum and minimum torque
references.
24.03 Maximum torq ref
24.04 Minimum torq ref
Define the times for the torque reference to increase
from zero to nominal motor torque (ramp up) and
vice versa (ramp down).
24.06 Torq ramp up
24.07 Torq ramp down
Analog input AI1/AI2 set-up (if either is selected as speed or torque reference source)
Define the filter time constant for the analog input. 13.01 AI1 filt time or
13.06 AI2 filt time
Define the maximum and minimum values for the
analog input.
13.02 AI1 max or
13.07 AI2 max
13.03 AI1 min or
13.08 AI2 min
63
%
100
T
t
O = I × (1 - e
-t/T
)
I = filter input (step)
O = filter output
t = time
T = filter time constant
Unfiltered signal
Filtered signal