Heat dissipation (option +C135)Air flow (option +C135)FrameACS880-
01-…
FrontHeatsinkFrontHeatsink
WWm
3
/hm
3
/h
276203475450R7119A-7
3752925120550R8142A-7
4353465120550R8174A-7
46537351701150R9210A-7
52542751701150R9271A-7
Connector and entry data for the power cables
IEC
Input, motor, resistor and DC cable terminal screw sizes, accepted wire sizes (per phase)
and tightening torques (T) are given below. l denotes stripping length inside the
connector.
Grounding ter-
minals
L1, L2, L3, T1/U, T2/V, T3/W
Cable entriesFrame
TMax.
wire
size
lT (wire screw)
Wire size
Ø *
pcs
N·mmm
2
mmN·mM…mm
2
mm
1.82580.6-0.75…6172R1
1.82580.6-0.75…6172R2
1.825101.7-0.5…16212R3
2.925183.3-0.5…35242R4
2.935185.6M86…70322R5
9.81853030M1025…150452R6
9.81853040
(30**)
M1095…240
(25…150**)
542R7
9.82×1853040M102 ×
(50…150)
454R8
9.82×1853070M122 ×
(95…240)
544R9
R-, R+/UDC+ and UDC- terminalsCable entriesFrame
lT (wire screw)Wire sizeØ *
pcs
mmN·mM…mm
2
mm
80.6-0.75…6171R1
80.6-0.75…6171R2
101.7-0.5…16211R3
Technical data 225