8 User’s manual – ACS880
01 democase
Parameters that need to be changed
Parameter
Name Setting Notes
95 HW configuration
95.01 Supply voltage [2] 380…415 V Correct rating settings made
91 Encoder module settings
91.11 Module 1 type [4] FEN-31
91.12 Module 1 location 003 FEN-31 location in Option slot 3
92 Encoder 1 configuration
92.01 Encoder 1 type [5] HTL
92.02 Encoder 1 source [1] Module 1
92.10 Pulses/revolution 1024
92.12 Speed calculation mode [0] A&B all
92.13 Position estimation enable [0] Disable
92.15 Transient filter [2] 1220 Hz
92.20 Enc cable fault func [0] No
After setting feedback parameters, activate settings with
91 Encoder 1 configuration
91.10 Encoder parameter refresh [1] Configure Will return to 'Done' after refresh
90 Feedback selection
90 .41 Motor feedback selection [1] Encoder 1
I/O settings
12 Standard AI
12.25 AI2 unit selection [2] V
12.28 AI2 max 10
Motor parameters and ID-run
99 Motor data
99.03 Motor type
[0] Asynchronous
motor
99.04 Motor ctrl mode [0] DTC
99.06 Motor nominal current 1.2 A
99.07 Motor nominal voltage 230 V
99.08 Motor nominal frequency 50 Hz
99.09 Motor nominal speed 1360 rpm
99.10 Motor nominal power 0.18 kW
99.11 Motor nominal cosfii 0.71
99.13 Identification run request [1] Normal Start ID-run in 'Remote' : Press DI1 ,
in 'Local' : Press panel Start button