20 ACS880-01/04 +C132 marine type-approved drives
Ratings – ACS880-04 +C132
The nominal ratings for marine type-approved ACS880-04 drive modules with 50 Hz
and 60 Hz supply at an ambient temperature of 45 °C (113 °F) are given below. The
symbols are described on page 21.
IEC RATINGS – ACS880-04 +C132
Drive
module
type
ACS880-
04
Frame
size
Input
rating
Max. current Output ratings
Nominal use Light-
overload use
Heavy-duty
use
I
1N
I
max
I
max_
start
I
N
P
N
I
Ld
P
Ld
I
Hd
P
Hd
A A A A kW A kW A kW
U
N
= 400 V
505A-3 R10 480 560 671 480 250 461 250 343 160
585A-3 R10 556 730 828 556 315 551 315 408 200
650A-3 R10 621 730 954 621 355 602 315 453 250
725A-3 R11 689 1020 1100 689 355 679 355 538 250
820A-3 R11 779 1020 1100 779 400 770 400 594 315
880A-3 R11 836 1100 1100 836 450 822 450 689* 355
U
N
= 500 V
460A-5 R10 437 560 671 437 250 428 250 314 200
503A-5 R10 480 560 671 478 315 459 315 343 200
583A-5 R10 556 730 828 554 355 544 355 393 250
635A-5 R10 618 730 954 603 400 592 400 453 315
715A-5 R11 689 850 1100 679 450 670 450 538 355
820A-5 R11 779 1020 1100 779 500 767 500 594 400
880A-5 R11 836 1100 1100 836 560 814 560 662** 450
U
N
= 690 V
330A-7 R10 314 480 510 314 250 304 250 242 200
370A-7 R10 352 520 650 352 315 342 315 309 250
430A-7 R10 409 540 720 409 400 399 355 342** 315
425A-7 R11 404 520 720 409 400 399 355 342 315
470A-7 R11 447 655 830 447 400 432 400 394 355
522A-7 R11 496 685 910 496 450 480 450 432 400
590A-7 R11 561 800 1010 561 500 542 500 480 450
650A-7 R11 618 820 1100 618 560 599 560 542** 500
721A-7 R11 685 825 1100 685 630 670 630 542** 500