EasyManua.ls Logo

ABB ACS880-04 - Maintenance Intervals

ABB ACS880-04
418 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
152 Maintenance
Maintenance intervals
The table below shows the maintenance tasks which can be done by the end user. The
complete maintenance schedule is available on the Internet
(www.abb.com/drivesservices
). For more information, consult your local ABB Service
representative (www.abb.com/searchchannels
).
Legend
I Inspection (visual inspection and maintenance action if needed)
P Performance of on/off-site work (commissioning, tests, measurements or other work)
R Replacement
Maintenance task/object Years from start-up
012
3456789101112
Cooling fans
Main cooling fan of D7T / D8T / R8i
module (speed-controlled)
R
Internal cooling fan for circuit boards
(R8i / D8T)
R
Cabinet cooling fan (internal, 50 Hz)
R
Cabinet cooling fan (internal, 60 Hz)
R R
Cabinet cooling fan (door, 50/60 Hz)
R
Cabinet cooling fan (IP54, 50 Hz)
R
Cabinet cooling fan (IP54, 60 Hz)
R R
Batteries
Control panel battery
R
Control unit battery
R R
Connections and environment
Cabinet door filters IP54
R R R R R R R R R R R R R
Quality of supply voltage
PPPPPPPPPPPPP
Spare parts
Spare parts
I I I I I I I I I I I I I
Reforming of DC circuit capacitors
(spare modules and spare capacitors)
PPPPPPPPPPPPP
Inspections by user
Cleaning IP22 and IP44 air inlet and
outlet meshes
I I I I I I I I I I I I I
Checking tightness of cable and busbar
terminals. Tightening if needed.
I I I I I I I I I I I I I
Checking ambient conditions (dustiness,
moisture, temperature)
I I I I I I I I I I I I I
Cleaning heatsinks of supply / inverter
module
I I I I I I I I I I I I I
Other
ABB-SACE main circuit breaker
maintenance
I I I I I I I I I I I I I
4FPS10000239703

Table of Contents

Other manuals for ABB ACS880-04

Related product manuals