Parameters 249
26.72 Torque reference
act 3
Displays the torque reference after the function applied by
parameter 26.13 Torque ref1 function (if any), and after
selection (26.14 Torque ref1/2 selection). See the control
chain diagram on page 589.
This parameter is read-only.
-
-1600.0 … 1600.0% Torque reference after selection. See par.
46.03
26.73 Torque reference
act 4
Displays the torque reference after application of reference
additive 1. See the control chain diagram on page 589.
This parameter is read-only.
-
-1600.0 … 1600.0% Torque reference after application of reference additive 1. See par.
46.03
26.74 Torque ref ramp out Displays the torque reference after limiting and ramping. See
the control chain diagram on page 589.
This parameter is read-only.
-
-1600.0 … 1600.0% Torque reference after limiting and ramping. See par.
46.03
26.75 Torque reference
act 5
Displays the torque reference after control mode selection.
See the control chain diagram on page 591.
This parameter is read-only.
-
-1600.0 … 1600.0% Torque reference after control mode selection. See par.
46.03
26.76 Torque reference
act 6
Displays the torque reference after application of reference
additive 2. See the control chain diagram on page 591.
This parameter is read-only.
-
-1600.0 … 1600.0% Torque reference after application of reference additive 2. See par.
46.03
26.77 Torque ref add A
actual
Displays the value of the source of torque reference additive
2. See the control chain diagram on page 591.
This parameter is read-only.
-
-1600.0 … 1600.0% Torque reference additive 2. See par.
46.03
26.78 Torque ref add B
actual
Displays the value of torque reference additive 2 before it is
added to torque reference. See the control chain diagram on
page 591.
This parameter is read-only.
-
-1600.0 … 1600.0% Torque reference additive 2. See par.
46.03
26.81 Rush control gain Rush controller gain term. See section Rush control (page
48).
10.0
0.0 …10000.0 Rush controller gain (0.0 = disabled). 1 = 1
26.82 Rush control
integration time
Rush controller integration time term. 2.0 s
0.0 10.0 s Rush controller integration time (0.0 = disabled). 1 = 1 s
No. Name/Value Description Def/FbEq16