268 Parameters
30.23 Minimum torque 2 Defines the minimum torque limit for the drive (in percent of
nominal motor torque) when
the source selected by parameter 30.18 Minimum torque
sel is 1, and
30.21 is set to Minimum torque 2.
Note: Do not set this parameter to 0% in an attempt to prevent
reverse rotation. In an open-loop application, that is likely to
prevent the motor from stopping altogether. To prevent
reverse rotation, use the speed/frequency limits in this
parameter group, or parameters 20.23/20.24.
See diagram at 30.18 Minimum torque sel.
-300.0%
-1600.0 … 0.0% Minimum torque limit 2. See par.
46.03
30.24 Maximum torque 2 Defines the maximum torque limit for the drive (in percent of
nominal motor torque) when
the source selected by parameter 30.25 Maximum torque
sel is 1, and
30.22 is set to Maximum torque 2.
See diagram at 30.18 Minimum torque sel.
300.0%
0.0 … 1600.0% Maximum torque limit 2. See par.
46.03
30.25 Maximum torque
sel
Selects a source that switches between two different
maximum torque limits.
0 = Maximum torque limit 1 defined by 30.20 is active
1 = Maximum torque limit selected by 30.22 is active
See also parameter 30.18 Minimum torque sel.
Maximum
torque 1
Maximum torque 1 0. 0
Maximum torque 2
source
1. 1
DI1 Digital input DI1 (10.02 DI delayed status, bit 0). 2
DI2 Digital input DI2 (10.02 DI delayed status, bit 1). 3
DI3 Digital input DI3 (10.02 DI delayed status, bit 2). 4
DI4 Digital input DI4 (10.02 DI delayed status, bit 3). 5
DI5 Digital input DI5 (10.02 DI delayed status, bit 4). 6
DI6 Digital input DI6 (10.02 DI delayed status
, bit 5). 7
DIO1 Digital input/output DIO1 (11.02 DIO delayed status, bit 0). 10
DIO2 Digital input/output DIO2 (11.02 DIO delayed status, bit 1). 11
Other [bit] Source selection (see Terms and abbreviations on page 114). -
30.26 Power motoring
limit
Defines the maximum shaft power in motoring mode, ie. when
power is being transferred from the motor to the machinery.
The value is given in percent of nominal motor power.
300.00%
0.00 … 600.00% Maximum shaft power in motoring mode. 1 = 1%
30.27 Power generating
limit
Defines the maximum shaft power in generating mode, ie.
when power is being transferred from the machinery to the
motor. The value is given in percent of nominal motor power.
Note: Do not set this parameter to 0% in an attempt to prevent
reverse rotation. In an open-loop application, that is likely to
prevent the motor from stopping altogether. To prevent
reverse rotation, use the speed/frequency limits in this
parameter group, or parameters 20.23/20.24.
-300.00%
-600.00 … 0.00% Maximum shaft power in generating mode. 1 = 1%
No. Name/Value Description Def/FbEq16