400 Parameters
91.21 Module 1 temp
sensor type
Specifies the type of temperature sensor connected to
interface module 1. Note that the module must also be
activated by parameters 91.1191.12.
None
None None. 0
PTC PTC. (The unit is ohms.) 1
KTY-84 KTY84. (The unit is selected by parameter 96.16 Unit
selection.)
2
91.22 Module 1 temp filter
time
Defines a filtering time for the temperature measurement
through interface module 1.
1500 ms
0…10000 ms Filtering time for temperature measurement. -
91.24 Module 2 temp
sensor type
Specifies the type of temperature sensor connected to
interface module 2. Note that the module must also be
activated by parameters 91.1391.14.
None
None None. 0
PTC PTC. (The unit is ohms.) 1
KTY-84 KTY84. (The unit is selected by parameter 96.16 Unit
selection.)
2
91.25 Module 2 temp filter
time
Defines a filtering time for the temperature measurement
through interface 2.
1500 ms
0…10000 ms Filtering time for temperature measurement. -
91.31 Module 1 TTL
output source
Selects the encoder input on interface module 1 whose signal
is echoed by or emulated to the TTL output.
See also section Encoder support (page 49).
Not selected
Not selected TTL output not in use. 0
Module input 1 Input 1 is echoed by or emulated to the TTL output. 1
Module input 2 Input 2 is echoed by or emulated to the TTL output. 2
91.32 Module 1 emulation
pulses/rev
Defines the number of TTL pulses per revolution for encoder
emulation output of interface module 1.
0
0…65535 Number of TTL pulses for emulation. 1 = 1
91.33 Module 1 emulated
Z-pulse offset
With interface module 1, defines when zero pulses are
emulated in relation to zero position received from the
encoder.
For example, with a value of 0.50000, a zero pulse is
emulated whenever the encoder position passes 0.5
revolutions. With a value of 0.00000, a zero pulse is emulated
whenever the encoder position passes zero position.
0.00000
0.00000 … 1.00000
rev
Position of emulated zero pulses. 32767 =
1rev
91.41 Module 2 TTL
output source
Selects the encoder input on interface module 2 whose signal
is echoed by or emulated to the TTL output.
See also section Encoder support (page 49).
Not selected
Not selected TTL output not in use. 0
Module input 1 Input 1 is echoed by or emulated to the TTL output. 1
Module input 2 Input 2 is echoed by or emulated to the TTL output. 2
91.42 Module 2 emulation
pulses/rev
Defines the number of TTL pulses per revolution for encoder
emulation output of interface module 2.
0
0…65535 Number of TTL pulses for emulation. 1 = 1