EasyManua.ls Logo

ABB ACS880-11 - Page 445

ABB ACS880-11
604 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Additional parameter data 445
01.68 Abs motor shaft power real32 0.00 … 32767.00 kW or hp 100 = 1 unit
01.70 Ambient temperature % real32 -200.00 … 200.00 % 100 = 1%
01.71 Step-up motor current real32 0.00 … 30000.00 A 100 = 1 A
01.72 U-phase RMS current real32 0.00 … 30000.00 A 100 = 1 A
01.73 V-phase RMS current real32 0.00 … 30000.00 A 100 = 1 A
01.74 W-phase RMS current real32 0.00 … 30000.00 A 100 = 1 A
(Parameters 01.10201.164 only visible when IGBT supply unit control activated by 95.20)
01.102 Line current real32 0.00 … 30000.00 A 100 = 1 A
01.104 Active current real32 0.00 … 30000.00 A 100 = 1 A
01.106 Reactive current real32 0.00 … 30000.00 A 100 = 1 A
01.108 Grid frequency real32 0.00 … 100.00 Hz 100 = 1 Hz
01.109 Grid voltage real32 0.00 … 2000.00 V 100 = 1 V
01.110 Grid apparent power real32 -30000.00 … 30000.00 kVA 100 = 1 kVA
01.112 Grid power real32 -30000.00 … 30000.00 kW 100 = 1 kW
01.114 Grid reactive power real32 -30000.00 … 30000.00 kvar 100 = 1 kvar
01.116 LSU cos Φ real32 -1.00 … 1.00 - 100 = 1
01.164 LSU nominal power real32 0…30000 kW 1 = 1 kW
03 Input references
03.01 Panel reference real32 -100000.00 … 100000.00 - 100 = 1
03.02 Panel reference 2 real32 -30000.00 … 30000.00 - 100 = 1
03.05 FB A reference 1 real32 -100000.00 … 100000.00 - 100 = 1
03.06 FB A reference 2 real32 -100000.00 … 100000.00 - 100 = 1
03.07 FB B reference 1 real32 -100000.00 … 100000.00 - 100 = 1
03.08 FB B reference 2 real32 -100000.00 … 100000.00 - 100 = 1
03.09 EFB reference 1 real32 -30000.00 … 30000.00 - 100 = 1
03.10 EFB reference 2 real32 -30000.00 … 30000.00 - 100 = 1
03.11 DDCS controller ref 1 real32 -30000.00 … 30000.00 - 100 = 1
03.12 DDCS controller ref 2 real32 -30000.00 … 30000.00 - 100 = 1
03.13 M/F or D2D ref1 real32 -30000.00 … 30000.00 - 100 = 1
03.14 M/F or D2D ref2 real32 -30000.00 … 30000.00 - 100 = 1
03.30 FB A reference 1 int32 int32 -2147483648 …
2147483647
-1 = 1
03.31 FB A reference 2 int32 int32 -2147483648 …
2147483647
-1 = 1
03.51 IEC application panel
reference
real32 -100000.0 … 100000.0 - 1 = 1
04 Warnings and faults
04.01 Tripping fault uint16 0000h…FFFFh - 1 = 1
04.02 Active fault 2 uint16 0000h…FFFFh - 1 = 1
04.03 Active fault 3 uint16 0000h…FFFFh - 1 = 1
04.04 Active fault 4 uint16 0000h…FFFFh - 1 = 1
04.05 Active fault 5 uint16 0000h…FFFFh - 1 = 1
No. Name Type Range Unit FbEq32

Table of Contents

Other manuals for ABB ACS880-11

Related product manuals