Parameters 423
DI6 Digital input DI6 (10.02 DI delayed status, bit 5). 7
DIO1 Digital input/output DIO1 (11.02 DIO delayed status, bit 0). 10
DIO2 Digital input/output DIO2 (11.02 DIO delayed status, bit 1). 11
Other [bit] Source selection (see Terms and abbreviations on page 114). -
96.13 User set I/O mode
in2
See parameter 96.12 User set I/O mode in1. Not selected
96.16 Unit selection Selects the unit of parameters indicating power, temperature
and torque.
0000 0000b
0000 0000b …
0001 0101b
Unit selection word. 1 = 1
96.20 Time sync primary
source
Defines the 1st priority external source for synchronization of
the drive’s time and date.
The date and time can also be directly set into 96.2496.26
in which case this parameter is ignored.
DDCS
Controller
Internal No external source selected. 0
DDCS Controller External controller. 1
Fieldbus A or B Fieldbus interface A or B. 2
Fieldbus A Fieldbus interface A. 3
Fieldbus B Fieldbus interface B. 4
D2D or M/F The master station on a master/follower or drive-to-drive link. 5
Embedded FB Embedded fieldbus interface. 6
Panel link Control panel, or Drive composer PC tool connected to the
control panel.
8
Ethernet tool link Drive composer PC tool through an FENA module. 9
96.23 M/F and D2D clock
synchronization
In the master drive, activates clock synchronization for
master/follower and drive-to-drive communication.
Inactive
Inactive Clock synchronization not active. 0
Active Clock synchronization active. 1
No. Name/Value Description Def/FbEq16
Bit Name Information
0 Power unit 0 = kW
1 = hp
1 Reserved
2 Temperature
unit
0 = C (°C)
1 = F (°F)
3 Reserved
4 Torque unit 0 = Nm (N·m)
1 = lbft (lbf·ft)
5…15 Reserved