174 Technical data
Contamination IEC/EN 60721-3-3:2002:
Classification of
environmental conditions
- Part 3-3: Classification
of groups of
environmental
parameters and their
severities - Stationary
use of weather protected
locations
IEC 60721-3-1 IEC 60721-3-2
Chemical gases Class 3C2 Class 1C2 Class 2C2
Solid particles Class 3S2 (3S1 with
IP20). No conductive
dust allowed.
Class 1S3 (packing must
support this, otherwise
1S2)
Class 2S2
Vibration
IEC 61800-5-1
IEC 60068-2-6:2007,
EN 60068-2-6:2008
Environmental testing Part
2: Tests –Test Fc: Vibration
(sinusoidal)
IEC/EN 60721-3-3:2002
10…57 Hz: max.
0.075 mm amplitude
57…150 Hz: 1 g
IEC/EN 60721-3-1:1997
10…57 Hz: max.
0.075 mm
amplitude 57…150 Hz: 1
g
IEC/EN 60721-3-2:1997
2…9 Hz: max. 3.5 mm
amplitude 9…20 Hz:
10 m/s2 (32.8 ft/s2)
Shock
IEC 60068-2-27:2008,
EN 60068-2-27:2009
Environmental testing -
Part 2-27: Tests - Test Ea
and guidance: Shock
Not allowed With packing max.
100 m/s
2
(330 ft./s
2
)
11 ms
With packing max.
100 m/s
2
(330 ft./s
2
)
11 ms
Auxiliary circuit power consumption
Cabinet heater and
lighting (options +G300
and +G301)
150 W
External uninterruptible
power supply (option
+G307)
150 W
Motor heater (option
+G313)
According to heater type
Materials
Cabinet Hot-dip zinc coated 1.5 mm thick steel sheet (thickness of coating approximately
100…200 micrometers). Polyester thermosetting powder coating (thickness
approximately 80 micrometers) on visible surfaces, color RAL 7035 and RAL
9017.
Busbars Tin-plated copper
Air filters of IP54 units Inlet (door) Outlet (roof)
Camfil/airComp 300-50
288 mm x 521 mm
688 mm x 521 mm
Camfil/airTex G150
2 pcs: 398 mm x 312 mm
Fire safety of materials
(IEC 60332-1)
Insulating materials and non-metallic items mostly self-extinctive