182 Parameters
14.76 AO1 actual value (Visible when 14.01 Module 1 type = FIO-11 or FAIO-01)
Displays the value of AO1 in mA.
This parameter is read-only.
-
0.000 22.000 mA Value of AO1. 1000 = 1 mA
14.77 AO1 source (Visible when 14.01 Module 1 type = FIO-11 or FAIO-01)
Selects a signal to be connected to analog output AO1.
Alternatively, sets the output to excitation mode to feed a
constant current to a temperature sensor.
Zero
Zero None. 0
Motor speed used 01.01 Motor speed used (page 117). 1
Output frequency 01.06 Output frequency (page 117). 3
Motor current 01.07 Motor current (page 117). 4
Motor torque 01.10 Motor torque (page 117). 6
DC voltage 01.11 DC voltage (page 117). 7
Power inu out 01.14 Output power (page 118). 8
Speed ref ramp in 23.01 Speed ref ramp input (page 220). 10
Speed ref ramp out 23.02 Speed ref ramp output (page 220). 11
Speed ref used 24.01 Used speed reference (page 226). 12
Torq ref used 26.02 Torque reference used (page 242). 13
Freq ref used 28.02
Frequency ref ramp output (page 250). 14
Process PID out 40.01 Process PID output actual (page 311). 16
Process PID fbk 40.02 Process PID feedback actual (page 311). 17
Process PID act 40.03 Process PID setpoint actual (page 311). 18
Process PID dev 40.04 Process PID deviation actual (page 311). 19
Force Pt100
excitation
The output is used to feed an excitation current to 1…3 Pt100
sensors. See section Motor thermal protection (page 80).
20
Force KTY84
excitation
The output is used to feed an excitation current to a KTY84
sensor. See section Motor thermal protection (page 80).
21
Force PTC
excitation
The output is used to feed an excitation current to 1…3 PTC
sensors. See section Motor thermal protection (page 80).
22
Force Pt1000
excitation
The output is used to feed an excitation current to 1…3
Pt1000 sensors. See section Motor thermal protection (page
80).
23
AO1 data storage 13.91 AO1 data storage (page 167). 37
AO2 data storage 13.92 AO2 data storage (page 167). 38
Other Source selection (see Terms and abbreviations on page 114). -
14.78 AO1 force data (Visible when 14.01 Module 1 type = FIO-11 or FAIO-01)
Forced value that can be used instead of the selected output
signal. See parameter 14.71
AO force selection.
0.000 mA
0.000 … 22.000 mA Forced value of analog output AO1. 1000 = 1 mA
No. Name/Value Description Def/FbEq16