428 Parameters
96.101 Confirm user pass
code
(Visible when user lock is open)
Confirms the new user pass code entered in 96.100 Change
user pass code.
10000000…
99999999
Confirmation of new user pass code. -
96.102 User lock
functionality
(Visible when user lock is open)
Selects the actions or functionalities to be prevented by the
user lock. Note that the changes made take effect only when
the user lock is closed. See parameter 96.02 Pass code.
Note: We recommend you select all the actions and
functionalities unless otherwise required by the application.
1000b
0000h…FFFFh Selection of actions to be prevented by user lock. -
96.108 LSU control board
boot
(Only visible when IGBT supply unit control activated by
95.20)
Changing the value of this parameter to 1 reboots the supply
control unit (without requiring a power off/on cycle of the drive
system).
The value reverts to 0 automatically.
0
0…1 1 = Reboot the supply control unit. 1 = 1
No. Name/Value Description Def/FbEq16
Bit Name Information
0 Disable ABB access
levels
1 = ABB access levels (service, advanced programmer, etc.; see
96.03) disabled
1 Freeze parameter
lock state
1 = Changing the parameter lock state prevented, ie. pass code
358 has no effect
2 Disable file
download
1 = Loading of files to drive prevented. This applies to
firmware upgrades
safety functions module (FSO-xx) configuration
parameter restore
loading an adaptive program
loading and debugging an application program
changing home view of control panel
editing drive texts
editing the favorite parameters list on control panel
configuration settings made through control panel such as
time/date formats and enabling/disabling clock display.
3 Disable FB write to
hidden
1 = Access to parameters on disabled access levels from fieldbus
prevented.
4…5 Reserved
6 Protect AP 1 = Creating a backup and restoring from a backup prevented.
7 Disable panel
Bluetooth
1 = Bluetooth disabled on ACS-AP-W control panel. If the drive is
part of a panel bus, Bluetooth is disabled on all panels.
8…10 Reserved
11 Disable OEM access
level 1
1 = OEM access level 1 disabled
12 Disable OEM access
level 2
1 = OEM access level 2 disabled
13 Disable OEM access
level 3
1 = OEM access level 3 disabled
14…15 Reserved