466 Additional parameter data
28.32 Constant frequency 7 real32 -500.00 … 500.00 Hz 100 = 1 Hz
28.41 Frequency ref safe real32 -500.00 … 500.00 Hz 100 = 1 Hz
28.51 Critical frequency function uint16 00b…11b - 1 = 1
28.52 Critical frequency 1 low real32 -500.00 … 500.00 Hz 100 = 1 Hz
28.53 Critical frequency 1 high real32 -500.00 … 500.00 Hz 100 = 1 Hz
28.54 Critical frequency 2 low real32 -500.00 … 500.00 Hz 100 = 1 Hz
28.55 Critical frequency 2 high real32 -500.00 … 500.00 Hz 100 = 1 Hz
28.56 Critical frequency 3 low real32 -500.00 … 500.00 Hz 100 = 1 Hz
28.57 Critical frequency 3 high real32 -500.00 … 500.00 Hz 100 = 1 Hz
28.71 Freq ramp set selection uint32 --1 = 1
28.72 Freq acceleration time 1 real32 0.000 …1800.000 s 1000 = 1 s
28.73 Freq deceleration time 1 real32 0.000 …1800.000 s 1000 = 1 s
28.74 Freq acceleration time 2 real32 0.000 …1800.000 s 1000 = 1 s
28.75 Freq deceleration time 2 real32 0.000 …1800.000 s 1000 = 1 s
28.76 Freq ramp in zero source uint32 --1 = 1
28.77 Freq ramp hold uint32 --1 = 1
28.78 Freq ramp output balancing real32 -500.00 … 500.00 Hz 100 = 1 Hz
28.79 Freq ramp out balancing
enable
uint32 --1 = 1
28.90 Frequency ref act 1 real32 -500.00 … 500.00 Hz 100 = 1 Hz
28.91 Frequency ref act 2 real32 -500.00 … 500.00 Hz 100 = 1 Hz
28.92 Frequency ref act 3 real32 -500.00 … 500.00 Hz 100 = 1 Hz
28.96 Frequency ref act 7 real32 -500.00 … 500.00 Hz 100 = 1 Hz
28.97 Frequency ref unlimited real32 -500.00 … 500.00 Hz 100 = 1 Hz
29 Voltage reference chain
(Group only visible with a BCU control unit)
29.01 Torque ref DC voltage control real32 -1600.0 … 1600.0 % 10 = 1%
29.02 DC voltage ref real32 0…2000 V 1 = 1 V
29.03 DC voltage ref used real32 0…2000 V 1 = 1 V
29.04 DC voltage ref ramped real32 0…2000 V 1 = 1 V
29.05 Filtered DC voltage real32 0…2000 V 1 = 1 V
29.06 DC voltage error real32 -2000…2000 V 1 = 1 V
29.07 Power reference real32 -300.00 … 300.00 % 100 = 1%
29.09 Minimum DC voltage
reference
real32 0…2000 V 1 = 1 V
29.10 Maximum DC voltage
reference
real32 0…2000 V 1 = 1 V
29.11 DC voltage ref1 source uint32 --1 = 1
29.12 DC voltage ref2 source uint32 --1 = 1
29.13 DC voltage ref1 function uint16 0…5 - 1 = 1
29.14 DC voltage ref1/2 selection uint32 --1 = 1
29.17 DC voltage filter time real32 0…10000 ms 1 = 1 ms
No. Name Type Range Unit FbEq32