514 Fault tracing
000E Encoder reported a position
counter error
See the documentation of the encoder.
000F Encoder reported an internal
error
See the documentation of the encoder.
A7EE Control panel loss
Programmable warning:
49.05 Communication loss
action
Control panel (or PC tool) has
stopped communicating.
Check PC tool or control panel
connection.
Check control panel connector.
Check mounting platform if being used.
Disconnect and reconnect the control
panel.
A880 Motor bearing
Programmable warnings:
33.14 On-time 1 warn
message
33.24 On-time 2 warn
message
33.55 Value counter 1
warn message
33.65 Value counter 2
warn message
Warning generated by an on-
time timer or a value counter.
Check the auxiliary code. Check the
source of the warning corresponding to
the code:
0: 33.13 On-time 1 source
1: 33.23 On-time 2 source
4: 33.53 Value counter 1 source
5: 33.63 Value counter 2 source.
A881 Output relay Warning generated by an edge
counter.
Programmable warnings:
33.35 Edge counter 1 warn
message
33.45 Edge counter 2 warn
message
Check the auxiliary code. Check the
source of the warning corresponding to
the code:
2: 33.33 Edge counter 1 source
3: 33.43 Edge counter 2 source.
A882 Motor starts
A883 Power ups
A884 Main contactor
A885 DC charge
A886 On-time 1
(Editable message text)
Programmable warning:
33.14 On-time 1 warn
message
Warning generated by on-time
timer 1.
Check the source of the warning
(parameter 33.13 On-time 1 source).
A887 On-time 2
(Editable message text)
Programmable warning:
33.24 On-time 2 warn
message
Warning generated by on-time
timer 2.
Check the source of the warning
(parameter 33.23 On-time 2 source).
A888 Edge counter 1
(Editable message text)
Programmable warning:
33.35 Edge counter 1
warn message
Warning generated by edge
counter 1.
Check the source of the warning
(parameter 33.33 Edge counter 1
source).
A889 Edge counter 2
(Editable message text)
Programmable warning:
33.45 Edge counter 2
warn message
Warning generated by edge
counter 2.
Check the source of the warning
(parameter 33.43 Edge counter 2
source).
A88A Value counter 1
(Editable message text)
Programmable warning:
33.55 Value counter 1
warn message
Warning generated by value
counter 1.
Check the source of the warning
(parameter 33.53 Value counter 1
source).
A88B Value counter 2
(Editable message text)
Programmable warning:
33.65 Value counter 2
warn message
Warning generated by value
counter 2.
Check the source of the warning
(parameter 33.63 Value counter 2
source).
Code
(hex)
Warning Cause What to do

Table of Contents