Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
12Bit 2 of 74.7 User Position control word 1.User Position CW1
bit 2
13Bit 3 of 74.7 User Position control word 1.User Position CW1
bit 3
14Bit 4 of 74.7 User Position control word 1.User Position CW1
bit 4
15Bit 5 of 74.7 User Position control word 1.User Position CW1
bit 5
16Bit 6 of 74.7 User Position control word 1.User Position CW1
bit 6
17Bit 7 of 74.7 User Position control word 1.User Position CW1
bit 7
0.000 units / real32Defines the expected latch position from axis shaft.Axis latch position78.11
1000 = 1 units / 1 = 1
units
Latch position from axis shaft.-2000000.000 ...
2000000.000 units
0.000 units / real32Defines the expected latch axis shaft position from the
master shaft probe.
Master latch
position
78.12
1000 = 1 units / 1 = 1
units
Latch axis shaft position from the master shaft probe.-2000000.000 ...
2000000.000 units
0.000 units / real32Defines the minimum threshold for the cyclic
correction. For example, if the minimum value is set to
30 degrees and the requested cyclic correction is 20
degrees, no correction is made.
Minimum correction78.13
1000 = 1 units / 1 = 1
units
Minimum threshold for the cyclic correction.0.000 ...
2000000.000 units
0.000 units / real32Defines the maximum threshold for cyclic correction.
For example, if the maximum value is set to 50 degrees
and the requested cyclic correction is 60 degrees, no
correction is made.
Maximum correction78.14
1000 = 1 units / 1 = 1
units
Maximum threshold for cyclic correction.0.000 ...
2000000.000 units
0.000 units / real32Defines the maximum correction value that can be
applied anytime after the first cyclic correction. This
can be used to calm down corrections in case there is
a jitter in the measurement. For example, if maximum
single correction value defined is 10 degrees and the
maximum cyclic correction value is 30 degrees, only 10
degrees is corrected at one cycle.
Maximum single
correction
78.15
1000 = 1 units / 1 = 1
units
Maximum correction value after the initial cyclic
correction.
0.000 ...
2000000.000 units
Parameters 461

Table of Contents

Related product manuals