PageContentsGroup
417
Settings for user load curve.
37 User load curve
420
Parameter values for process PID control.
40 Process PID set 1
435
A second set of parameter values for process PID control.
41 Process PID set 2
438
Settings for the internal brake chopper.
43 Brake chopper
441
Configuration of mechanical brake control.
44 Mechanical brake control
447
Settings for the energy saving calculators.
45 Energy efficiency
451
Speed supervision settings; actual signal filtering; general scaling
settings.
46 Monitoring/scaling
settings
456
Data storage parameters that can be written to and read from
using other parameters’ source and target settings.
47 Data storage
459
Communication settings for the control panel port on the drive.
49 Panel port communication
463
Fieldbus communication configuration.
50 Fieldbus adapter (FBA)
472
Fieldbus adapter A configuration.
51 FBA A settings
474
Selection of data to be transferred from drive to fieldbus
controller through fieldbus adapter A.
52 FBA A data in
475
Selection of data to be transferred from fieldbus controller to
drive through fieldbus adapter A.
53 FBA A data out
476
Fieldbus adapter B configuration.
54 FBA B settings
478
Selection of data to be transferred from drive to fieldbus
controller through fieldbus adapter B.
55 FBA B data in
479
Selection of data to be transferred from fieldbus controller to
drive through fieldbus adapter B.
56 FBA B data out
480
Configuration of the embedded fieldbus (EFB) interface.
58 Embedded fieldbus
489
DDCS communication configuration.
60 DDCS communication
505
Defines the data sent to the DDCS link.
61 D2D and DDCS transmit
data
510
Mapping of data received through the DDCS link.
62 D2D and DDCS receive
data
519
Enables ESP function parameters.
74 ESP control
525
Controls frequency/speed reference settings of a drive.
75 ESP reference setup
532
Enables ESP automatic control.
See section ESP production mode.
76 ESP automatic control
537
Enables/Disables Underload and Overload protection functions.
79 Load protection
546
Monitors voltage in the motor.
80 Voltage control
552
Enables pump cleaning function.
81 Pump cleaning
559
Estimates flowrate of pump curves in ESP application.
85 Q-H pump curves
565
Motor and load feedback configuration.
90 Feedback selection
576
Configuration of encoder interface modules.
91 Encoder module settings
580
Settings for encoder 1.
92 Encoder 1 configuration
587
Settings for encoder 2.
93 Encoder 2 configuration
589
Control of the supply unit of the drive, such as DC voltage and
reactive power reference.
94 LSU control
172 Parameters