Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
- / uint16ACS800-compatible warning (alarm) word 1.
The bit assignments of this word correspond to ALARM
WORD 1 in the ACS800. Parameter 4.120 Fault/Warning
word compatibility determines whether the
assignments are according to the ACS800 Standard or
ACS800 System control program.
Each may indicate several ACS880 warnings as listed
below.
This parameter is read-only.
ACS880
events indic-
ated by this
bit
(see Fault tra-
cing(page649).
ACS800 alarm name
Bit
(4.120 =
ACS800 Sys-
tem ctrl pro-
gram)
(4.120 =
ACS800
Standard ctrl
program)
A5A0START INHIBITSTART INHIBIT0
AFE1, AFE2EM STOPReserved1
A491, A497,
A498, A499
MOTOR TEMP
M
THERMISTOR2
A492MOTOR TEMPMOTOR TEMP3
A2BA, A4A9,
A4B0, A4B1,
A4F6
ACS800 TEMPACS800 TEMP4
A797, A7B0,
A7B1, A7E1
ENCODER ERRENCODER ERR5
A490, A5EA,
A782, A8A0
T MEAS CIRCT MEAS ALM6
-DIGITAL IOReserved7
-ANALOG IOReserved8
-EXT DIGITAL
IO
Reserved9
A6E5, A7AA,
A7AB
EXT ANALOG
IO
Reserved10
A7CB, AF80CH2 COMM
LOSS
Reserved11
A981MPROT
SWITCH
COMM MOD-
ULE
12
-EM STOP DECReserved13
A2B3EARTH FAULTEARTH FAULT14
A983SAFETY
SWITC
Reserved15