EasyManua.ls Logo

ABB ACS880 - Page 186

ABB ACS880
764 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
- / uint16ACS800-compatible warning (alarm) word 2.
The bit assignments of this word correspond to ALARM
WORD 2 in the ACS800. Parameter 4.120 Fault/Warning
word compatibility determines whether the bit
assignments are according to the ACS800 Standard or
ACS800 System control program.
Each may indicate several ACS880 warnings as listed
below.
This parameter is read-only.
ACS880
events indic-
ated by this
bit
(see Fault tra-
cing(page649).
ACS800 alarm name
Bit
(4.120 =
ACS800 Sys-
tem ctrl pro-
gram)
(4.120 =
ACS800
Standard ctrl
program)
A781MOTOR FANReserved0
-UNDERLOADUNDERLOAD1
-INV OVER-
LOAD
Reserved2
A480CABLE TEMPReserved3
-ENCODER
A<>B
ENCODER4
A984FAN OVER-
TEMP
Reserved5
-ReservedReserved6
-POWFAIL FILEPOWFAIL FILE7
-POWDOWN
FILE
ALM (OS_17)8
A780MOTORSTALLMOTOR STALL9
A8A0AI<MIN FUNCAI < MIN FUNC10
A6D1, A6D2,
A7C1, A7C2,
A7CA, A7CE
COMM MOD-
ULE
Reserved11
-BATT FAILUREReserved12
A7EEPANEL LOSSPANEL LOSS13
A3A2DC UNDER-
VOLT
Reserved14
-RESTARTEDReserved15
Warning word 24.32
- / uint16User-defined event word. This word collects the status
of the events (warnings, faults or pure events) selected
by parameters 4.414.72.
For each event, an auxiliary code can optionally be
specified for filtering.
This parameter is read-only.
Event word 14.40
1 = Event selected by parameters 4.41 Event word 1 bit
0 code (and 4.42 Event word 1 bit 0 aux code) is active
is active
User bit 0b0
1 = Event selected by parameters 4.43 Event word 1 bit
1 code (and 4.44 Event word 1 bit 1 aux code) is active
User bit 1b1
1 = Event selected by parameters 4.71 (and 4.72) is
active
User bit 15b15
1 = 10000h…FFFFh
186 Parameters

Table of Contents

Other manuals for ABB ACS880