Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
61.10 Motor torque (page 174).Motor torque
71.11 DC voltage (page 175).DC voltage
81.14 Output power (page 175).Power inu out
1023.1 Speed ref ramp input (page 311).Speed ref ramp in
1123.2 Speed ref ramp output (page 311).Speed ref ramp out
1224.1 Used speed reference (page 318).Speed ref used
1326.2 Torque reference used (page 338).Torq ref used
1428.2 Frequency ref ramp output (page 347).Freq ref used
1640.1 Process PID output actual (page 420).Process PID out
1740.2 Process PID feedback actual (page 420).Process PID fbk
1840.3 Process PID setpoint actual (page 420).Process PID act
1940.4 Process PID deviation actual (page 420).Process PID dev
See Terms and abbreviations (page 169).Other [value]
0.000 / real32Defines the real value of the signal (selected by
parameter 11.55 Freq out 1 source and shown by
parameter 11.54 Freq out 1 actual value) that
corresponds to the minimum value of frequency output
1 (defined by parameter 11.60 Freq out 1 at src min).
f
out
(
11.54
)
11.61
11.60
11.58
11.59
Signal (real)
selected by
par.
11.55
f
out
(
11.54
)
11.61
11.60
11.59 11.58
Signal (real)
selected by
par.
11.55
Freq out 1 src min11.58
1 = 1 / 1000 = 1Real signal value corresponding to minimum value of
frequency output 1.
-32768.000 ...
32767.000
222 Parameters