EasyManua.ls Logo

ABB ACS880 - Frequency Reference Chain

ABB ACS880
764 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
Settings for the frequency reference chain.Frequency
reference chain
28
See the control chain diagrams 756 and 757.
- / real32Displays the used frequency reference before ramping.
See the control chain diagram on page 757.
Frequency ref ramp
input
28.1
This parameter is read-only.
- / -Frequency reference before ramping. For scaling, see
parameter 46.2.
-598.00 ... 598.00 Hz
- / real32Displays the final frequency reference (after selection,
limitation and ramping). See the control chain diagram
on page 757.
Frequency ref ramp
output
28.2
This parameter is read-only.
- / -Final frequency reference. For scaling, see parameter
46.2.
-598.00 ... 598.00 Hz
P.9.21 / uint32Selects frequency reference source 1.
Two signal sources can be defined by this parameter
and 28.12 Frequency ref2 source. A digital source
Frequency ref1
source
28.11
selected by 28.14 Frequency ref1/2 selection can be
used to switch between the two sources, or a
mathematical function (28.13 Frequency ref1 function)
applied to the two signals to create the reference.
0
AI
FB
Other
28.11
28.12
28.13
28.90
28.91
28.14
28.92
Ref1
ADD
SUB
MUL
MIN
MAX
0
AI
FB
Other
0
1
0None.Zero
112.12 AI1 scaled value (page 226).AI1 scaled
212.22 AI2 scaled value (page 228).AI2 scaled
43.5 FB A reference 1 (page 179).FB A ref1
53.6 FB A reference 2 (page 179).FB A ref2
83.9 EFB reference 1 (page 179).EFB ref1
93.10 EFB reference 2 (page 179).EFB ref2
103.11 DDCS controller ref 1 (page 179).DDCS ctrl ref1
113.12 DDCS controller ref 2 (page 179).DDCS ctrl ref2
123.13 M/F or D2D ref1 (page 180).M/F reference 1
133.14 M/F or D2D ref2 (page 180).M/F reference 2
Parameters 347

Table of Contents

Other manuals for ABB ACS880

Related product manuals