Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
12Parameter 74.1 ESP control word (page 519), bit 15 status
controls enable/disable status of the function.
ESP CW bit 15
See Terms and abbreviations (page 169).Other [bit]
0.0 min / real32Defines the time for the motor to stay ON.
After the ON cycle is over, drive will automatically shut
down and switch to 74.52 Off time counter.
On time74.51
1 = 1 min / 10 = 1 minOn time.0.0 ... 90000.0 min
0.00 min / real32Defines the time for the motor to stay OFF.
After the OFF cycle is over, drive will automatically shut
down and switch to 74.51 On time counter.
Off time74.52
1 = 1 min / 10 = 1 minOff time.0.0 ... 90000.0 min
Not selected / unit32Defines the source for the Fly start check enable signal.
The function will check the actual motor speed before
making decision on starting procedure.
If the speed is outside safe-to-restart speed region,
then the control program logic will skip starting
routines and get in to production state from the current
motor speed.
Note: This parameter setting has no effect in case
parameter 74.30 Speed observer enable is ON. Since
the Fly-start speed check employs backspin observer
function to check the speed. Also, by activating this
parameter will delay normal start of the drive for the
time necessary to perform measurement defined in
parameter 74.39 Measurement delay.
Fly-start speed
check
74.79
0Flying start check function is disabled.Not selected
1Flying start check function is enabled.Selected
2Digital input DI1 (10.2 DI delayed status, bit 0).DI1
3Digital input DI2 (10.2 DI delayed status, bit 1).DI2
4Digital input DI3 (10.2 DI delayed status, bit 2).DI3
5Digital input DI4 (10.2 DI delayed status, bit 3).DI4
6Digital input DI5 (10.2 DI delayed status, bit 4).DI5
7Digital input DI6 (10.2 DI delayed status, bit 5).DI6
10Digital input/output DIO1 (11.2 DIO delayed status, bit
0).
DIO1
11Digital input/output DIO2 (11.2 DIO delayed status, bit
1).
DIO2
See Terms and abbreviations (page 169).Other [bit]
0.00 Hz / real32Displays the speed measured by the Backspin Speed
Observer function.
This parameter is read-only.
Observer speed
measured
74.80
100 = 1 Hz / 10 = 1 HzObserver speed measured.0.00 ... 598.00 Hz
- / unit16Displays status word of the functions controlling ESP
specific start/stop logic.
ESP start/stop sw74.99
Parameters 523