Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
Enables ESP automatic control.ESP automatic
control
76
See section ESP production mode.
ESP CW bit 14 /
unit32
Defines the source for the auto mode enable signal.Auto mode enable76.01
0Current pulse start mode enable is inactive.Not selected
1Current pulse start mode enable is active.Selected
2Digital input DI1 (10.2 DI delayed status, bit 0).DI1
3Digital input DI2 (10.2 DI delayed status, bit 1).DI2
4Digital input DI3 (10.2 DI delayed status, bit 2).DI3
5Digital input DI4 (10.2 DI delayed status, bit 3).DI4
6Digital input DI5 (10.2 DI delayed status, bit 4).DI5
7Digital input DI6 (10.2 DI delayed status, bit 5).DI6
10Digital input/output DIO1 (11.2 DIO delayed status, bit
0).
DIO1
11Digital input/output DIO2 (11.2 DIO delayed status, bit
1).
DIO2
12Parameter 74.1 ESP control word (page 519), bit 14
status controls enable/disable status of the function.
ESP CW bit 14
See Terms and abbreviations (page 169).Other [bit]
Process control 1 /
unit32
Defines source for the signal to select desired process
control mode.
Process control sel76.02
0Process control 1 is selected.Process control 1
1Process control 2 is selected.Process control 2
2Digital input DI1 (10.2 DI delayed status, bit 0).DI1
3Digital input DI2 (10.2 DI delayed status, bit 1).DI2
4Digital input DI3 (10.2 DI delayed status, bit 2).DI3
5Digital input DI4 (10.2 DI delayed status, bit 3).DI4
6Digital input DI5 (10.2 DI delayed status, bit 4).DI5
7Digital input DI6 (10.2 DI delayed status, bit 5).DI6
8Digital input/output DIO1 (11.2 DIO delayed status, bit
0).
DIO1
9Digital input/output DIO2 (11.2 DIO delayed status, bit
1).
DIO2
See Terms and abbreviations (page 169).Other [bit]
- / real32Defines the delay time before ESP control program
activates the process control mode selected with
parameter 76.01 Auto mode enable.
Auto mode start
delay
76.11
After the drive is started during the time set in this
parameter, the automatic process control remains
inactive. The pump motor will follow speed reference
selected in parameter 75.11 Pump speed ref source.
1 = 1 s / 1 = 1 sAutomode start delay.0...30000 s