Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
1Channel A: Rising and falling edges are used for speed
calculation.
*Channel B: Defines the direction of rotation.
A all
2Channel A: Rising edges are used for speed calculation.
*Channel B: Defines the direction of rotation.
A rising
3Channel A: Falling edges are used for speed calculation.
*Channel B: Defines the direction of rotation.
A falling
4One of the above modes is selected automatically
depending on the pulse frequency as follows:
Used mode
Pulse frequency of the
channel(s)
A&B all< 2442 Hz
A all2442…4884 Hz
A rising> 4884 Hz
Auto rising
5One of the above modes is selected automatically
depending on the pulse frequency as follows:
Used mode
Pulse frequency of the
channel(s)
A&B all< 2442 Hz
A all2442…4884 Hz
A falling> 4884 Hz
Auto falling
0 / uint16(Visible when 92.1 Encoder 1 type = Absolute encoder)
Defines the number of bits used to indicate position
within one revolution. For example, a setting of 15 bits
corresponds to 32768 positions per revolution.
The value is used when parameter 92.11 Absolute
position source is set to EnDat, Hiperface or SSI. When
parameter 92.11 Absolute position source is set to
Tamagawa, this parameter is internally set to 17.
Note: With an EnDat or HIPERFACE encoder and FEN-11
FPGA version VIE12200 or later, this parameter is
automatically set upon validation of encoder settings
(91.10 Encoder parameter refresh).
Position data width92.13
1 = 1 / 1 = 1Number of bits used in position indication within one
revolution.
0...32
Enable / uint16(Visible when 92.1 Encoder 1 type = HTL 1)
Selects whether position estimation is used with
encoder 1 to increase position data resolution or not.
Position estimation
enable
92.13
0Measured position used. (The resolution is 4 × pulses
per revolution for quadrature encoders, 2 × pulses per
revolution for single-track encoders.)
Disable