Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
0.00 uF / real32Defines the capacitance of a custom sine filter, i.e. when
parameter 95.15 Special HW settings bit 3 is activated.
If the capacitors are star/wye-connected, enter the
capacitance of one leg into the parameter.
If the capacitors are delta-connected, multiply the
capacitance of one leg by 3 and enter the result into
the parameter.
Note: For an ABB sine filter (95.15 Special HW settings
bit 1), this parameter is set automatically and should
not be adjusted.
Sine filter
capacitance
99.19
100 = 1 uF / 100 = 1
uF
Capacitance of custom sine filter.0.00 ... 100000.00 uF
Done / uint16Selects the option to calculate the required low voltage
side data.
Note: All ESP circuitry related parameters (listed below)
must be updated before this calculation.
Parameters:
• 95.01, 95.40, 95.200 (if known), 95.201,
95.202...95.204 (if known)
• 99.18, 99.19, 99.201...99.207
Med-voltage side
data
99.200
0Requested action is completed. No more action
required.
Done
1Low voltage side data is calculated using the medium
voltage side data.
Calculate and apply
0.0 A / real32Defines nominal current of the ESP motor. This setting
must match the value on the rating plate of the motor.
ESP motor nominal
current
99.201
10 = 1 A / 10 = 1 ANominal current of the ESP motor.0.0 ... 6400.0 A
Parameters 629