AQUAMASTER4 | ELECTROMAGNETIC FLOWMETER FLANGED SENSOR | OI/FEW400/FRV-EN REV. A
15
Burying a sensor
When burying a sensor, ensure it can be found easily if required
(for example, mark the installation position with a post).
Installing a protection plate above the meter is also
recommended.
CAUTION
For further advice when burying sensors, contact the
ABB Service Organization.
Backfill
Protection
plate
recommended
Figure 26 Underground installations
Sensor separation
If F-, V-, R-style sensors are installed in adjacent pipelines,
ensure they are at least 0.7 m (2.3 ft) apart to prevent the
electromagnetic field from one meter affecting the other.
0.7 m (2.3 ft) M in.
Figure 27 Sensor separation