42 CI/FCB300/FCH300-EN Rev. F | CoriolisMaster FCB330, FCB350, FCH330, FCH350
8.4 Flowmeter sensor model FCB300 / FCH300
8.4.1 Temperature class
Model FCx3xx-F1…, in Class I Div. 1
Temperature class
T3 185 °C (365 °F) 180 °C (356 °F) 180 °C (356 °F)
T6 65 °C (149 °F) 65 °C (149 °F) 60 °C (140 °F)
Model FCx3xx-F2…, in Class I Div. 2
Ambient temperature ≤40 °C (≤104 °F) ≤50 °C (≤122 °F) ≤60 °C (≤140 °F)
Temperature class
T2 200 °C (392 °F) 200 °C (392 °F) 180 °C (356 °F)
T3 180 °C (356 °F) 180 °C (356 °F) 180 °C (356 °F)
T4 115 °C (239 °F) 115 °C (239 °F) 115 °C (239 °F)
T5 80 °C (176 °F) 80 °C (176 °F) 75 °C (167 °F)
Ambient and process conditions:
-20 ... 60 °C (-4 ... 140 °F)
-40 ... 60 °C (-40 ... 140 °F) (only for integral mount design devices)
-50 ... 200 °C (-58 ... 392 °F)
IP 65, IP 67, and NEMA 4X / Type 4X
IMPORTANT (NOTE)
In the case of the remote mount design, the signal cable between the flowmeter sensor and the transmitter must measure at
least 5 m (16.4 ft) in length. Install conduit seals within 18” (45 cm).