Refitting the tubular cover (-10/1.52 and -12/1.27)
NoteAction
O-ring: 3HAC061327-076Wipe, lubricate and fit the o-ring to its groove.1
O-ring: 3HAB3772-166Replace if damaged.
Grease: 3HAC042536-001 (Shell
Gadus S2)
xx2300000846
xx2300000847
Hex socket head cap screw:
3HAB3409-224
Refit the covers with new attachment screws.2
M3x12 12.9 Lafre 2C2B/FC6.9 (3
pcs)
Tightening torque: 1.4 Nm.
xx2000002123
Continues on next page
1024 Product manual - CRB 15000
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.6.7 Replacing the axis-5 joint unit and the axis-5 to axis-6 transition cabling
Continued