2 Select Template configuration.
xx2100000715
3 Review that the template configuration is suitable for the intended application.
If modifications are needed, see Modify a configuration on page 124.
Note
A SafeMove configuration must always be validated to verify that the desired
safety is achieved. If no validation is performed, or the validation is
inadequate, the configuration cannot be relied on for personal safety.
4 If the template configuration is suitable, select Write to controller.
The safety report is presented on the screen.
5 Save the safety report. Print out and sign this safety report.
See ABB Safety Configuration Report on page 130. More information about
the safety report and how to validate is described in Application
manual - Functional safety and SafeMove.
6 Select Apply to controller to proceed.
The controller is automatically restarted when applying the configuration.
Modify a configuration
Use the following procedure to modify a loaded configuration and apply it to the
robot controller.
1 Select Enable Edit Mode to edit the safety configuration.
2 If no configuration is loaded, load an empty configuration or a template
configuration.
Continues on next page
124 Product manual - CRB 15000
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
3 Installation and commissioning
3.6.3 The SafeMove configurator app on FlexPendant
Continued