2 Navigate to the function ISH_n_Speed_In_WarningArea_mm_s and set its
value from default 250 to any required value.
xx2200000437
3 Save the change and apply to the controller.
The speed limit can also be changed in SafeMove configurations using the following
procedure:
1 Open the RobotStudio.
2 Log in the controller using the Admin account and request the write access.
3 In the Controller tab, choose Visual SafeMove from the Safety group in the
Configuration category.
4 In the left pane of the window, choose Global_TSP under the Tool Speed
Supervisions from the navigation tree.
xx2200000438
Continues on next page
Product manual - CRB 15000 179
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
3 Installation and commissioning
3.6.8 Use cases of safety configurations
Continued