xx2000002009
Disconnect the connectors from the drive board.
D1.X1 from X1
D1.DC+ from DC+
D1.DC- from ground
D1.X4 from X4
D1.X2 from X2
D1.X5 from X5
DR.X8 from X8
CAUTION
Use tweezers to unlock connectors and pull them
off.
4
Removing the joint cable
NoteAction
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section The
unit is sensitive to ESD on page 53.
1
Protection plate: 3HAC077790-001
(for CRB 15000-5/0.95) /
3HAC087789-001 (for CRB 15000-
10/1.52 and CRB 15000-12/1.27)
Fit the protection plate to the drive board unit.
Tip
Using the protection plate is important for protect-
ing the drive board unit. If complete joint unit is
to be replaced, the protection plate is not needed.
2
xx2000002057
Continues on next page
236 Product manual - CRB 15000
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.