Removing the arm-side interface
NoteAction
CAUTION
Make sure that all supplies for electrical power
are turned off.
1
CAUTION
There is cabling connected between the arm-side
interface and the joint unit drive board.
Open the arm-side interface with care to avoid
damage to the cabling or the connector(s).
Do not leave the arm-side interface in location
without being secured with the attachment screws.
2
xx2000002550
Remove the attachment screws.3
xx2100000335
Loosen the arm-side interface carefully and dis-
connect the connectors from it.
ASI.DC+
ASI.DC-
ASI.X1
4
Disconnecting the axis-6 joint unit cabling
NoteAction
xx2000002161
Cut the cable ties.1