Closing the housing top cover
NoteAction
Gasket: 3HAC075056-001Check the inner plate gasket.1
xx2000002095
Replace if damaged.
Hex socket head cap screw: M3x8
12.9 Lafre 2C2B/FC6.9 (4 pcs).
Refit the inner plate with the screws.2
Tightening torque: 1.4 Nm
xx2000002076
Hex socket head cap screw: M3x8
12.9 Lafre 2C2B/FC6.9 (4 pcs).
Refit the cover with the four screws.3
Tightening torque: 0.45 Nm
xx2000002075
Preparations before fitting the joint unit
NoteAction
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section The
unit is sensitive to ESD on page 53.
1
Continues on next page
Product manual - CRB 15000 545
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.4.2 Replacing the housing
Continued