NoteAction
Cleaning agent: IsopropanolValid for CRB 15000-5/0.952
Flange sealant: Loctite 574Clean the mounting surface with isopropanol.
xx2000001973
Apply flange sealant to the corner of the lower
arm mounting surface, as pointed out in the figure.
xx2000001970
Lift the upper arm into mounting position while
inserting the cabling into the lower arm.
3
Slide the upper arm into place on the guide pins.4
Hex socket head cap flange screw:
M4x25 12.9 Lafre
2C2B/FC6.9+PrO-COat111 (16 pcs)
Secure the upper arm to the lower arm with all
attachment screws but two.
Pre-tighten the screws crosswise firstly.
5
xx2000001969
Hex socket head cap flange screw:
M4x25 12.9 Lafre
2C2B/FC6.9+PrO-COat111 (16 pcs)
Remove the guide pins and fasten the remaining
two screws.
6
xx2000001967
Tightening torque: 4.6 NmTorque tighten all screws crosswise.7