Connecting the tubular cabling
NoteAction
xx2000002120
Reconnect the connectors to the drive board.
D3/4.DC+ to DC+
D3/4.DC- to Ground
D3/4.X2 to X2
1
xx2000002067
Connect the connectors to each other and snap
them to the cable holders.
J3.DC+ to J3.DC+
J3.DC- to J3.DC-
J3.CS to J3.CS
J3.CP to J3.CP
2
Hex socket head cap screw: M3x6
(1 pcs).
Secure the cables for functional earth and protect-
ive earth with a screw.
3
Tightening torque: 0.8 Nm.
xx2000001945
Continues on next page
Product manual - CRB 15000 593
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.4.3 Replacing the tubular
Continued