5.4.4 Replacing the wrist housing
Location of the wrist
The wrist is located as shown in the figure.
xx2100000053
Summary of the replacement procedure
This is a brief summary of the replacement procedure, containing the major actions
to be performed.
1 Remove the tubular cover.
2 Separate the cabling between the tubular and the tilt (at the axis-4 joint unit).
3 Remove the tilt and place on a workbench.
4 Remove the axis-6 joint unit.
Continues on next page
Product manual - CRB 15000 597
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.4.4 Replacing the wrist housing