NoteAction
Lift away the swing.
CAUTION
The torque sensor (on the exposed PCBA) is
sensitive to mechanical damage. Handle the as-
sembly with care.
5
Refitting the swing (-5/0.95)
Use these procedures to refit the swing.
Refitting the swing(-5/0.95)
NoteAction
Cleaning agent: IsopropanolClean the mounting surface with isopropanol.1
Flange sealant: Loctite 574Apply flange sealant to the corner of the base
mounting surface, as pointed out in the figure.
xx2000001990
Separate the new swing parts by removing the
pre-assembling screws.
2
xx2000001989
Refit the swing to the base unit, aligning the pin
with the pin hole.
CAUTION
The torque sensor (on the exposed PCBA) is
sensitive to mechanical damage. Handle the as-
sembly with care.
3
Continues on next page
Product manual - CRB 15000 743
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.5.2 Replacing the swing
Continued